Header 1a Header 1b Header 1c Header 1c
Header Middle 1a Header Middle 1b Header Middle 1c
Top Navi
celah
celah
celah
Navy Bottom
Blank

Server Facility & Design:
IRFA Media WWW Promotion
PRODUCTS 
 
  SPP | E M U | ITT A-C | ITT Bell & Gossett | ITT Flygt | dp pumps 
Pumps Projects
Professional Fire Protection
blank blank blank
 

 

A SHARED TRADITION OF EXCELLENCE

One of the first fire trucks built in the late 1800's was equipped with an A-C Fire Pump.

For over 80 years, A-C Fire Pump Systems has been on the forefront in developing, designing and custom-building a wide range of fire pump systems including prefabricated packages and house units that meet every fire protection need.
Also, these packages may play a key role in saving lives and preventing further to house insurance covered establishments and even those that are not.
A-C Fire Pump is not only rich in history, but on the cutting edge of new technology as demonstrated with our contribution to the fire protection systems for launch pads 39A and 39B for NASA at the Kennedy Space Center.
A-C Fire Pump Systems furnished a package of four 12x8x22 9100 series horizontal splitcase pumps driven by huge 1065 horsepower diesel engines including state-of-the-art control systems.
Each pump is rated at 3,500 gallons per minute at 250 psi pressure.

We will continue to be the leader in the fire protection industry providing both excellent service and superior products for years to come.
You can always count on A-C Fire Pump Systems to solve your pumping problems.

Fire Mans
 
Decade  Nasa
 



 
 
   
In-Line Pumps
 
Capacity to 750 GPM (892 L/min)
Pressures to 165 PSI (116 m)
Working Pressures to 150 PSI
 
Bullet   Space saving design
Bullet   No foundation or pads required
Bullet   Suction and discharge flanges are on a common centerline, 180° apart for inline mounting in piping
Bullet   Top pullout design allows for fast and easy servicing. The rotating element is easily removed without disturbing suction and discharge piping
Bullet   Self-venting design eliminates the need for an automatic air release valve
Bullet   Bronze impeller is dynamically balanced and keyed to the motor shaft
   
In-Line Pump




   
End Suction Pumps
 
Capacity to 500 GPM
(892 L/min)
Pressures to 150 PSI (106 m)
Working Pressures to 150 PSI
 
Bullet Top centerline discharge with foot supported casing
  - Ease of installation
  - Simplifies piping layout
  - Reduces problems associated with piping strain
Bullet Self-venting design eliminates the need for automatic air release valve
Bullet Rear pullout design supplied as standard with spacer coupling
  - Ease of maintenance, eliminates disturbing driver or piping when removing rotating element
Bullet Hydraulically balanced impeller extends bearing life and assures smoother operation
Bullet Available in electric motor or diesel engine driven configuration
End Suction Pumps
End Suction Pumps
 



 
   
Vertical Turbine Pumps
 
Capacity to 5000 GPM
(18,925 L/min)
Pressures to 500 PSI (353 m)
Working Pressures
  - up to 200 PSI with 125 lb. A.S.A. flanges
  - up to 550 PSI with 250 lb. A.S.A. flanges
 
Bullet   Required by NFPA when operating under a static suction lift condition
Bullet   Dynamically balanced impellers secured to the shaft with steel locking collets to assure proper problem free operation
Bullet   Open lineshaft design provides for product lubrication of the bearings
Bullet   Available in electric motor or diesel engine driven configuration
Bullet   Provided with a bronze suction strainer as standard
Bullet   Provided with an oversized air release valve as standard
Bullet   Available in special materials of construction for salt water applications
   
Vertical Turbine Pump
 



 
Split Case Pumps
   
8100 Series
 
Capacity to 3000 GPM
(11,355 L/min)
Pressures to 255 PSI (179 m)
Working Pressures
  - up to 250 PSI (176m) with 125 lb. A.S.A. flanges
  - up to 375 PSI (264) with 250 lb. A.S.A. flanges
 
Bullet   Space saving design
Bullet   Available in horizontal or vertical configuration
Bullet   Suction and discharge flanges are on a common centerline
Bullet   Bearing span is kept to a minimum
Bullet   Available in electric motor driven or engine driven configuration
Bullet   Available in clockwise or counter-clockwise rotation to simplify pump room layout
   
8100 Series




 
   
9100 Series
 
Capacity to 5000 GPM
(18,925 L/min)
Pressures to 208 PSI (146 m)
Working Pressures
  - up to 175 PSI (146) with 125 lb. A.S.A. flanges
  - up to 255 PSI (180) with 250 lb. A.S.A. flanges
 
Bullet   Space saving design
Bullet   Suction and discharge flanges are on a common centerline
Bullet   Dual volute casing balances radial forces on the shaft and bearings
Bullet   Available in electric motor driven or engine driven configuration
Bullet   Available in clockwise or counter-clockwise rotation to simplify pump room layout
   
9100 Series




 
   
8200 Series
 
Capacity to 1000 GPM
(3,785 L/min)
Pressures to 640 PSI (450 m)
Working Pressures
  - up to 500 PSI (352) with 250 lb. A.S.A. flanges
  - up to 800 PSI (563) with 800 lb. A.S.A. flanges
 
Bullet   Space saving design
Bullet   Suction and discharge flanges are on a common centerline
Bullet   Bearing span is kept to a minimum
Bullet   Compact pump design
Bullet   Dual volute casing balances radial forces on the shaft and bearings
Bullet   Available in electric motor driven or engine driven configuration
Bullet   Two stage pump with two impellers threaded together
Bullet   Dynamically balanced impellers
Bullet   Available in clockwise or counter-clockwise rotation to simplify pump room layout
   
8200 Series




 
Skid Packages
   
Select A-C Fire Pumps with confidence...
With A-C Fire Pumps Systems you can rest assured of start-up and future product support being available locally, worldwide
Skid Packages Skid Packages
   
   
Bullet   Components of A-C Fire Pump Systems are labeled by one or more of the following testing labo- ratories: Underwriters Laboratories (UL), Underwriters Laboratories Canada (ULC), Factory Mutual (FM)
Bullet   The equipment is completely manufactured at our ISO 9001 facility
Bullet   Packaged systems are performance and hydrostatically tested at our manufacturing facility prior to shipment
Bullet   Certified welding is available per ASME section IX
Bullet   Our fire pump packages have been seismic qualification tested
Bullet   Computer and CAD Design capabilities assist you in the design of a system custom built to your specification. Complete drawings are furnished for your approval prior to manufacture
Bullet   International distribution and start up capabilities




 
House Packages
   
"Big House"
The largest pre-packed complete house unit ever built.
This system includes three electric motor driven fire pump, 16' x 53' and weighs 57,000 lbs.
Pump House Packages

 
Versatility-a key word at A-C Fire Pump Sytems.

We realize that each customer has different fire protection needs, specific to each fire hazard. We can design a system around your needs, just like the Saturn automotive plant... special buildings, pump materials and custom floor arrangements.
You need it - we'll provide it.
   





blank Package Systems blank
 
   
Complette House Units
Complete House Units pre-wired and pre-piped--instant suppression
 
Bullet   Engine combustion air intake vent
Bullet   Battery operated emergency lights
Bullet   A115V thermostat control ventilating fan
Bullet   Single point power connection
Bullet   Exterior photocell sodium vapor light
Bullet   Pre-piped sprinkler systems for pump house interior
Bullet   GFCI utility electrical outlets provided
Bullet   Base is provided with optional lifting provisions
Bullet   Building heater
   
Vertical Turbine Package
Vertical Turbine Package
 
All A-C Fire Pumps are performance and hydrostatically tested in accordance with the requirements of NFPA #20 and are supplied as standard with a packed stuff box, grease lubricated bearings and cast iron / bronze fitted materials of construction.


NFPA #20 requires the use of a vertical turbine on systems operating under a static suction lift condition requirement. A-C Fire Pump Systems offers the complete pre-packaged system, pump, driver, controller, flow measuring device, control valves, check valves, sensing lines and power distribution panel.
This system requires one electrical connection and a water supply.
It's ready to provide immediate, reliable fire protection.
 

 
     
 
  SPP | E M U | ITT A-C | ITT Bell & Gossett | ITT Flygt | dp pumps 
 
Blank
Blank
Copyright © 2002 - PT. MULTI SINDOMULYA - ALLRIGHT RESERVED
Last Update: July 2009
Best view at: 800 x 600 dpi resolution